3TH Contactor Relays
Choice and ordering knowledge | ||||||||||||
AC operation |
3TH80 |
3TH82 |
3TH40 |
3TH42 |
3TH30 |
|||||||
Order No. | 3TH80 40 – 0X
3TH80 31 – 0X 3TH80 22 – 0X 3TH80 13 – 0X 3TH80 04 – 0X |
3TH82 80
3TH82 71 3TH82 62 3TH82 53 3TH82 44 |
|
3TH40 40 – 0X
3TH40 31 – 0X 3TH40 22 – 0X 3TH40 13 – 0X 3TH40 04 – 0X |
3TH42 80 – 0X
3TH42 71 – 0X 3TH42 62 – 0X 3TH42 53 – 0X 3TH42 44 – 0X |
3TH30 40 – 0X
3TH30 31 – 0X 3TH30 22 – 0X |
||||||
Rated insulation voltage | 660 | 660 | 690 | 690 | 690 | |||||||
Rated operational present (380V) | AC – 15 (AC – 11) | 6 | 6 | 6 | 6 | 6 | ||||||
DC – 13 (DC – 11) | zero.25 | zero.25 | zero.25 | zero.25 | zero.25 | |||||||
Mechanical endurance (x106) | 15 | 15 | 30 | 30 | 30 | |||||||
Electrical endurance (x106) | AC – 15 (AC – 11) | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | ||||||
Switching frequency (1/h) | AC – three | 1000 | 1000 | 1000 | 1000 | 1000 | ||||||
AC – 15 DC – 13 | 3600 | 3600 | 3600 | 3600 | 3600 | |||||||
Coil voltage tolerance (AC) | (zero.eight~ 1.1)Us | |||||||||||
Order No. suffixes for rated management voltages for coils
3TH3 -0X 3TH4 -0X 3TH8 -0X |
Coils for five
50Hz |
60Hz | Hz | 60 | Coils
Hz |
for 60Hz 50Hz | Coils | for 50/60Hz | ||||
24V 29V 32V 38V 36V 42V 42V 50V 48V 58V 60V 72V
110V 132V 125/127V 150/152V 220V 264V 230V 277V 240V 288V 380V 460V 400V 480V 415V 500V 500V 600V |
B0
C0 G0 D0 H0 E0 F0 L0 M0 P0 U0 Q0 V0 R0 S0 |
1
1 1 2 2 2 2 four 5 |
24V
10V 15V 20V 08V 20V 30V 40V 40V 75V |
20V
92V 96V 100V 173V 183V 192V 200V 367V 480V |
C1
G1 J1 K1 M1 N1 L1 P1 R1 S1 |
24V
42V 110V 115V 120V 208V 220V 230V 240V 440V 575V |
C2
D2 G2 J2 K2 M2 N2 L2 P2 R2 S2 |
|||||
Energy consumption of coil (50Hz) | Closed | 10 | 10 | 10 | 10 | 10 | ||||||
p.f. | zero.29 | zero.29 | zero.29 | zero.29 | zero.29 | |||||||
Closing | 68 | 68 | 68 | 68 | 69 | |||||||
p.f. | zero.82 | zero.82 | zero.82 | zero.82 | zero.82 | |||||||
Typical thermal present (A) |
Choice and ordering knowledge | ||||||||||||
DC operation |
3TH40 |
3TH42 |
3TH30 |
|||||||||
Order No. | 3TH40 40 – 1X
3TH40 31 – 1X 3TH40 22 – 1X |
3TH42 80 – 1X
3TH42 71 – 1X 3TH42 62 – 1X |
3TH30 40 – 1X
3TH30 31 – 1X |
|||||||||
3TH40 13 – 1X | 3TH42 53 – 1X | 3TH30 22 – 1X | ||||||||||
3TH40 04 – 1X | 3TH42 44 – 1X | |||||||||||
Rated insulation voltage | 690 | 690 | 690 | |||||||||
Rated operational present (A) (380V) | AC – 15 (AC – 11) | 6 | 6 | 6 | ||||||||
DC – 13 (DC – 11) | zero.25 | zero.25 | zero.25 | |||||||||
Mechanical endurance (x106) | 30 | 30 | 30 | |||||||||
Electrical endurance (x106) | AC – 15 (AC – 11) | S ee technical information on 6/four. | ||||||||||
Switching frequency (1/h) | AC – three | 1000 | 1000 | 1000 | ||||||||
AC – 15
DC – 13 |
3600 | 3600 | 3600 | |||||||||
Coil voltage tolerance (AC) | (zero.eight~ 1.1)Us | |||||||||||
Order No. suffixes for rated management voltages for coils
3TH3 -1X 3TH4 -1X |
Rated V DC
management voltage 12 21.5 |
24 30 | 36 42 48 | 60 110 | 125 180 220 230 240 250 | |||||||
Order No. suffix A4 U4 | B4 C4 | V4 D4 W4 | E4 F4 | G4 K4 M4 P4 This autumn N4 | ||||||||
Energy consumption
of coil (50Hz) |
Closing and closed (W) | 6.2 | 6.2 | 6.2 | ||||||||
Typical thermal c | urrent (A) | 16 | 16 | 16 | ||||||||
Auxiliary contact bl | ocks | |||||||||||
When extra cont be chosen.
(Please concentrate t As much as four auxiliary conta unit. For element of 3TX4 |
acts are wanted 3TX4 sort auxiliary contacts can
o: solely 3TH30 can use 3TX4). ct blocks will be plugged onto the 3TH30 fundamental , check with chapter 3TF AC contactors. |
|||||||||||
Kind | Order No. | NO | NC | 3TX4010 – 3A with change place indicator. | ||||||||
3TX4 |
3TX 40 10 – 2A
3TX 40 01 – 2A 3TX 40 10 – 3A * |
1
– 1 |
–
1 – |
|||||||||
3TH Contactor Relays
3TH Contactor Relays
Contact preparations | ||||||
Kind | Construction | NO | NC | |||
3TH40 04 | 3TH80 04 | One tier | zero | four | ||
3TH40 13 | 3TH80 13 | 1 | three | |||
3TH40 22 | 3TH80 22 | 2 | 2 | |||
3TH40 31 | 3TH80 31 | three | 1 | |||
3TH40 40 | 3TH80 40 | four | zero | |||
3TH42 44 | 3TH82 44 | Two tier | four | four | ||
3TH42 53 | 3TH82 53 | 5 | three | |||
3TH42 62 | 3TH82 62 | 6 | 2 | |||
3TH42 71 | 3TH82 71 | 7 | 1 | |||
3TH42 80 | 3TH82 80 | eight | zero | |||
3TH30 40 | One tier | four | zero | |||
3TH30 31 | three | 1 | ||||
3TH30 22 | 2 | 2 | ||||
Rationalization of MLFB | ||||||
Code of coil’s voltages: 0X – AC, 1X – DC
Variety of NC contacts Variety of NO contacts 30, 40, 80 point out four pairs of contacts. 42, 82 point out eight pairs of contacts Contactor relays |
||||||
Technical knowledge | ||||||