توضیحات

دانلود دفترچه کنتاکتور کمکی اشنایدر مدل LADN04

 

Product information sheet LADN04

Complementary

Business Standing Commercialised
Vary of product TeSys D

TeSys D management relay

TeSys F

Product or part sort Auxiliary contact block
Product compatibility CR1F
Auxiliary contacts operation Instantaneous
Pole contact composition four NC
Connections – terminals Screw clamp terminals 2 cable 1…2.5 mm² – cable stiffness: stable – with out cable finish

Screw clamp terminals 2 cable 1…2.5 mm² – cable stiffness: strong – with cable finish

Screw clamp terminals 2 cable 1…2.5 mm² – cable stiffness: versatile – with out cable finish

Screw clamp terminals 2 cable 1…2.5 mm² – cable stiffness: versatile – with cable finish

Screw clamp terminals 1 cable 1…2.5 mm² – cable stiffness: stable – with out cable finish

Screw clamp terminals 1 cable 1…2.5 mm² – cable stiffness: stable – with cable finish

Screw clamp terminals 1 cable 1…2.5 mm² – cable stiffness: versatile – with out cable finish

Screw clamp terminals 1 cable 1…2.5 mm² – cable stiffness: versatile – with cable finish

Mounting location Entrance
[Ui] rated insulation voltage 600 V – certifications CSA

690 V – conforming to IEC 60947-5-1

600 V – certifications UL

[Ue] rated operational voltage 690 V AC 25…400 Hz
[Ith] typical free air thermal present 10 A at <= 60 °C
Irms rated making capability 250 A at <= 690 V DC conforming to IEC 60947-5-1

140 A at <= 690 V AC conforming to IEC 60947-5-1

Permissible short-time ranking 140 A at -5…60 °C 100 ms

120 A at -5…60 °C 500 ms

100 A at -5…60 °C 1 s

Safety sort GG fuse <= 10 A score in accordance with operational present for Ue <= 690 V
Related fuse ranking IEC 60947-5-1
Mechanical sturdiness 30 Mcycles
Minimal switching present 5 mA
Minimal switching voltage 17 V
Non-overlap time 1.5 ms on energisation (no overlap between NC and NO contact)

1.5 ms on de-energisation (no overlap between NC and NO contact)

Overlap time 1.5 ms
Insulation resistance > 10 MOhm
Product weight zero.05 kg
Nov 7, 2013 1

Traits TeSys D – auxiliary contact block – four NC screw clamp terminals

Important

Environmental attribute Regular surroundings
Requirements BS 4794

EN 60947-5-1

IEC 60947-5-1

NF C 63-140

VDE 0660

Product certifications CSA UL
IP diploma of safety IP2x conforming to VDE 0106
Protecting remedy TH conforming to IEC 60068
Ambient air temperature for operation -5…60 °C
Ambient air temperature for storage -60…80 °C
Working altitude 3000 m with out derating in temperature
RoHS compliance
RoHS EUR standing Compliant
RoHS EUR conformity date(YYWW) 0629
Contractual guarantee
Interval 18 months
2

 

 

 

توضیحات تکمیلی
برند

SCHNEIDER

نظرات (0)

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “کنتاکتور کمکی اشنایدر مدل LADN04”